SolvisMax Solo
The All-Rounder
SolvisMax Solo
This product can only be used in combination with a SolvisMax Charging Module!
Stratified heat storage tank, with boiler flange for retrofitting a burner, for energy efficient heat management. Exceptionally suitable for connecting further heat sources, e.g. a solar energy system and/or a wood burning stove. Temperature driven charging/discharging of the stratified storage tank by means of a self regulating, maintenance free stratified charger with a European patent. Ready for connection of hot water generation system and continuous circulation balancing. Comprising:
• Storage tank made from S235JR, primed exterior, raw interior
• Blind flange for retrofitting a boiler
• Solar stratified charger
• Stratified charger for the return lines from heating circuits and hot water station • Sensor sleeves for inserting the SolvisControl storage tank sensors
• Insulation and robust cladding
• Adjustable tank feet to compensate for an irregular floor
The thermal storage tank together with the charging module form a SolvisMax system. The storage tank has a continuous insulating jacket for minimal heat loss. All pipe connections are positioned in the bottom third of the tank. They are located under the insulation and outside the storage tank to avoid heat loss from a weakening of the insulation. The tank connections can optionally be placed on the left or right.
Note:
One of the following charging modules must be purchased separately:
28119 LM-BAS
27743 LM-24 or 27745 LM-36
27742 LM-24-P or 27744 LM-36-P
31641 LM-30-WP or 31639 LM-30-WP-P
Memory size BW-457 only with LM-24/LM-30 or LM-24-P/LM-30-P or
LM-BAS combinable
The SX-457 capacity storage tank can only be combined with LM-24 or LM-24-P. By using third party boiler, need additional sensor (Product No. 27738), please separately order it.
Products available:
SolvisMax Solo 457 - Volume: 475L
SolvisMax Solo 757 - Volume:757L
SolvisMax Solo 957 - Volume: 957L
SolvisMax Solo - Summary of Dimensions
SL-457 | SL-757 | SL-957 | |||
Rated volume | Litre | 450 | 750 | 950 | |
Actual volume | Litre | 475 | 730 | 919 | |
Storage tank distribution | |||||
Hot water standby volume | Litre | 96 | 171 | 82 / 212 / 301 Configured by sensor positioning | |
Heating buffer volume | Litre | 22 | 34 | 34 | |
Solar buffer volume | Litre | 352 | 512 | 793 / 663 / 574 | |
Performance specifications | |||||
Tank material | S235JR, primed exterior, raw interior | ||||
Heating flow/return connection | 28 mm pipe | ||||
Cold/hot drinking water connection | 28 mm pipe | ||||
Max. operating pressure | 3 bar | ||||
Max. operating temperature | 95 °C | ||||
Maximum heating flow/return volume flow | 2 m³/h | ||||
Dimensions | |||||
Max. width | mm | 870 | 1020 | ||
Max. depth | mm | 1380 | 1550 | ||
Max. height | mm | 1800 | 1920 | 2300 | |
Tilt height without insulation | mm | 1670 | 1760 | 2140 | |
Diameter without insulation | mm | 650 | 790 | ||
Minimum front spacing | mm | 500 | |||
Minimum side/rear spacing | mm | 300 | |||